Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 52(3): 423-429, 2021 May.
Artigo em Chinês | MEDLINE | ID: mdl-34018360

RESUMO

OBJECTIVE: To investigate the differences in the osteogenic capacity of osteoporotic adipose-derived stem cells (OP-ASCs) and normal control adipose-derived stem cells (Ctrl-ASCs), and to examine the expression levels of RNA methyltransferase like 14 (Mettl14) and the Notch signaling molecule 1 (Notch1). METHODS: The osteoporosis (OP) model of SD rats was established with ovariectomy (OVX). Micro-CT, HE staining and Masson staining were performed to identify the successful establishment of the OP model, OP-ASCs and Ctrl-ASCs were isolated and cultured adherently. Then, the three-way differentiation capacity of the adipose-derived stem cells (ASCs) was determined through alizarin red staining, alcian blue staining and oil red O staining and flow cytometry was conducted to examine the surface antigens CD29, CD44, CD90, CD31, CD34, and CD45. Alizarin red staining and comparison of the mRNA and protein expression of Run-related transcription factor 2 (Runx2) were done to explore the differences in osteogenic potential of OP-ASCs and Ctrl-ASCs. Real-time PCR and Western blot were performed to explore the expression differences of Mettl14 and Notch1 at mRNA and protein levels between OP-ASCs and Ctrl-ASCs. RESULTS: Micro-CT, HE and Masson staining results showed that the number of trabecular bone decreased and the spacing increased in the tibias of the osteoporosis group (OP group) compared with those of the control group (Ctrl group), indicating that the OP model was established successfully. Three-way differentiation and flow cytometry results confirmed the successful isolation and culture of ASCs. After osteogenic induction, alizarin red staining showed that OP-ASCs had fewer number and more scattered distribution of mineralized nodules than Ctrl-ASCs did. The expression of Runx2 in OP-ASCs was lower than that in Ctrl-ASCs ( P<0.05). Mettl14 as well as Notch1 showed lower expression in OP-ASCs than they did in Ctrl-ASCs ( P<0.05). CONCLUSION: The osteogenic capacity of OP-ASCs was lower compared with that of Ctrl-ASCs, Mettl14 expression of OP-ASCs was decreased compared with that of Ctrl-ASCs, and the Notch signaling pathway was inhibited in OP-ASCs. The study helps build the foundation for further investigation in the specific mechanisms of Mettl14 and Notch1 during osteogenic differentiation of OP-ASCs.


Assuntos
Osteogênese , Células-Tronco , Adipócitos , Tecido Adiposo , Animais , Diferenciação Celular , Células Cultivadas , Feminino , Humanos , Metiltransferases , Ratos , Ratos Sprague-Dawley , Receptor Notch1/genética
2.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 38(2): 170-176, 2020 Apr 01.
Artigo em Chinês | MEDLINE | ID: mdl-32314891

RESUMO

OBJECTIVE: To study the precision of digital guide plates applied to the implant surgery of anterior teeth. METHODS: Fifty patients scheduled to receive implant restoration treatment in anterior teeth were enrolled in this study and divided into two groups (n=25, each group): those who were given routine implant restoration treatment (control group, 45 implants) and those who received implant restoration treatment using a digital guide plate (test group, 51 implants). After implantation, planned and placed implants were superimposed using digital software, and deviations (corona, apex, depth, degree) were analyzed. Esthetic parameters were assessed at 1 week (baseline), 6 month, and 1 year post final restoration. Pink esthetic (PES) and white esthetic (WES) scores were respectively used to evaluate the soft tissue and restoration esthetic outcome. RESULTS: The deviation parameters in the test group were significantly lower than those in the control group (P<0.05). PES and WES values recorded for the control group at 1 week, 6 month, and 1 year post final restoration were significantly lower than those in the test group (P<0.05). CONCLUSIONS: The digital guide plate can improve the accuracy of the three-dimensional position of implants in the maxillary esthetic zone. As such, this device may play an important role in obtaining the ideal aesthetic effects of maxillary anterior teeth.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Coroas , Estética Dentária , Humanos , Maxila , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...